Location and Size of Bubble
Number / 1,000 cm3
Core Region (=core + inner cladding)
(See Note 1.5)
Outer Cladding Region
(=interface + outer cladding)
~ 0.5 mm
No Count
0.5 ~ 1.0 mm
≤ 10
1.0 ~ 1.5 mm
≤ 2
1.5 ~ 2.0 mm
≤ 1.0
2.1 mm ~
(See Note 1.5)
When the drawing conditions and the measurement conditions are optimum and stable, the preforms shall be expected to meet the target fiber specifications as shown in Table 2.1.
Item |
Requirements |
|
|
1 |
Attenuation at 1310 nm |
≤ 0.34 dB/km |
|
Attenuation at 1383 nm |
≤ 0.34 dB/km |
(Note 2.1) |
|
Attenuation at 1550 nm |
≤ 0.20 dB/km |
|
|
Attenuation at 1625 nm |
≤ 0.23 dB/km |
|
|
Uniformity of Attenuation |
≤ 0.05 dB/km at 1310&1550 nm |
|
|
2 |
Mode Field Diameter at 1310 nm |
9.1± 0.4 µm |
|
3 |
Cable Cutoff Wavelength (λcc) |
≤ 1260 nm |
|
4 |
Zero Dispersion Wavelength (λ0) |
1300 ~ 1324 nm |
|
5 |
Dispersion at 1285~1340 nm |
-3.8 ~ 3.5 ps/(nm·km) |
|
6 |
Dispersion 1550 nm |
13.3 ~ 18.6 ps/(nm·km) |
|
7 |
Dispersion 1625 nm |
17.2 ~ 23.7 ps/(nm·km) |
|
8 |
Dispersion Slope at λ0 |
0.073 ~ 0.092 ps/(nm2·km) |
|
9 |
Core Concentricity Error |
≤ 0.6 µm |
Note 2.1: The attenuation at 1383 nm after hydrogen aging test shall not be included in the Table 2.1 because it highly depends on the fiber drawing conditions.