The collector transceiver antenna transmits and receives the electromagnetic wave signal, completes the temperature acquisition.
Signal transmission of collector and temperature sensor. Used together with the temperature collector, Ann C is installed in the same compartment of the sensor, responsible for communication with the sensor antenna, complete the sending and receiving of excitation signal and sensor signal.
Plat Panel Antenna 1(left) | Plat Panel antenna2(right) | |
Frequency range | 422MHz–442MHz | 423MHz–443MHz |
Center Frequency | 433MHz | 433MHz |
Maximum gain | >3.5dBi | >2.8dBi |
Resident bobby | <2.0 | <2.0 |
Nominal impedance | 50Ω | 50Ω |
Power range | 50 W | 50 w |
Radiation direction | In all directions | In all directions |
Appearance size | 208*178*50mm | 207*73*28mm |
Temperature range | ~40C~+85C | ~40C~+85C |
Joint mode | SMA external thread bore | SMA external thread bore |
Connection feeder | RG-174 2m | RG-174 2m |
Switch installation location | Outlet room and other space is relatively full grid area | Busbar room spec relatively narrow area |
Temperature sensor according to the way of installation, models are divided into: Tuning fork sensor, bundled sensor, self-locking fastening sensor for different environments. According to the temperature range ans installation location, can be divided into ordinary type and high temperature type, corresponding to the detection of bus bar, moving contact temperature. The movable contact mounting type sensor is fixed on the plum blossom contact finger of the mobile contact of the hand cart cabinet.
Temperature sensor(movable contact mounting type)
Sensor frequency | 12 frequencies, 424 to 441 MHz |
Temperature range | 0C~180C |
Measuring precision | Main 1C(0~120C); Earth 2C(120~180C) |
Temperature resolution | 0.1C |
Outline dimension | Minimum:28.1*16.5mm No 8 |
Storage temperature | ~25C~190C, Note: high temperature storage affects life |
The temperature collector produces the electromagnetic wave signal corresponding to the frequency of the temperature sensor. The electromagnet wave signal with temperature information returned by the temperature sensor is received and the temperature signal is analyzed and transmitted to the temperature measurement management device at the station end. The collector communicates with a group of sensors downlink and transmits RF pulse. The signal reflected by the sensors is processed in the well, and finally the effective temperature information is resolved.
Number of antenna | 2 |
Number of sensors | Max. 12 sensors per antenna, max. 24 sensors for 2 antennas |
RF power | Max. 11dBm(10mW) |
RF frequency | 424~441MHz |
Communication interface | RS485 bus/Nbit wireless/WIFI wireless options |
Communication protocol | MODBUS-RTU |
Sampling frequency | Min 1s, configurable |
Power supply | DC12V/0. 2A or DC5V/0.4A |
Minimum size | 98*88*38mm |
Installation mode | C45 rail clamping fixation |