1.1.1 TECHNICAL PARAMETERS
● Support HomeplugAV2 Protocol standard
● Industrial DIN rail style installation
● The maximum transfer distance up to 500 meters.
● Self-adapt the rate
1.1.2 MANAGEABILITY
● Quality of Service(QoS) 。
● IGMO(IPv4)Snooping&MLD(IPv6)Snooping
1.1.3 WORKING ENVIRONMENT
● Working temperature: -40℃-80℃。
● Operating humidity: 10%-85% no condense.
● Storage humidity:5%-90% no condens
1.1.4 DESIGN STANDARDS
IEC 60529 IEC 50022 IEC 60068-2-6 HomeplugAV2
1.1.5 TECHNICAL PARAMETERS
Model |
WD-1201M-DIN(D) |
Interface |
1*LAN 10/100/1000Base-TX self adaption RJ45,1*DC power interface |
LED display light |
Ethernet, PLC link ,Power |
Transfer frequency |
2-68MHz MIMO |
Protocol(PHY) |
IEEE802.3,IEEE802.3x, IEEE802.3u HomeplugAV2 |
Security |
128-AES |
Number of each group |
Up to 63 |
installation |
Rail TS35 |
Protection level |
IP40 |
Modulation |
OFDM |
Effective transfer rate |
TCP/IP 500Mbps |
Manageability |
802.1D Ethernet Bridge |
Quality of Service(QoS) |
IGMO(IPv4)Snooping&MLD(IPv6)Snooping |
Voltage range |
DC 10V-80V |
Operating temperature |
-40℃-85℃ |
Size |
123*97*47(mm)(L×W×H) |
Weight |
0.25kg |
Operating environment |
Operating humidity:10%-85% (no condense) |
1.2 FEATURES
(1) Packet loss:≤0.1%(100M,load 70%).
(2) Support 7*24 hours all weather operation.
(3) Hardware watch dog function.
(4) PING≤20MS.
1.3 IMMUNITY OF ESD
The testing voltage which the device should be beared: ±6kV direct Discharge, ±8kV air discharge. Discharge number in Each sensitive testing point: Plus-n-Minus 10 times each, Every time the discharge interval is 1 s, according to B/T 17626.2-2006.
1.4 IMMUNITY OF ELECTRICAL FAST TRANSIENT IMPULSE GROUP(COMMON MODE)
The testing voltage which the device should be beared:
between the power supply voltage port and ground: ±2.0kV;
between signal circuit and ground: ±1.0kV;
repetition frequency: 5KHz, test duration: 1 min/ time;
testing times: Plus-n-Minus 5 times each. According to GB/T 17626.4-2008.
1.5 ANTI INTERFERENCE OF SURGE IMPACT
The testing voltage which the device should be beared: ±2kV;
The interval of continuous impulses: 1min/time;
Test number: Plus-n-Minus 5 times each. According to GB/T 17626.5-2008.(protection: all models protection and varistor series of
discharge tube type)
1.6 ANTI- VIBRATION
Meet the demand of MX3 in TB1433(0-200Hz,2g acceleration, maximum amplitude 7mm), interface with no loose, device with no Sealing off and drop in the test