China WD-1201M-DIN(D) Manufacturer and Supplier | TCT

WD-1201M-DIN(D)

Short Description:

DIN rail mounting industrial powerline ethernet bridge is an industrial power line communication product developed by Kunshan Wondertek Technology Co., LTD. The product supports the HomeplugAV2 communication protocol standard. At present, it has been widely used in railway, mining, industrial communication, airport, subway, coal mine, intelligent storage, industrial automation control, automatic garage and other wired or sliding contact line and many other sites.

Industrial scenarios, Recommended to use with blocking Filter


Product Detail

Product Tags

1.1.1 TECHNICAL PARAMETERS

● Support HomeplugAV2 Protocol standard
● Industrial DIN rail style installation
● The maximum transfer distance up to 500 meters.
● Self-adapt the rate

1.1.2 MANAGEABILITY

● Quality of Service(QoS) 。
● IGMO(IPv4)Snooping&MLD(IPv6)Snooping

1.1.3 WORKING ENVIRONMENT

● Working temperature: -40℃-80℃。
● Operating humidity: 10%-85% no condense.
● Storage humidity:5%-90% no condens

1.1.4 DESIGN STANDARDS

IEC 60529       IEC 50022     IEC 60068-2-6   HomeplugAV2

1.1.5 TECHNICAL PARAMETERS

Model WD-1201M-DIN(D)
Interface 1*LAN 10/100/1000Base-TX self adaption RJ45,1*DC power interface
LED display light Ethernet, PLC link ,Power
Transfer frequency 2-68MHz  MIMO
Protocol(PHY) IEEE802.3,IEEE802.3x, IEEE802.3u  HomeplugAV2
Security 128-AES
Number of each group Up to 63
installation Rail TS35
Protection level IP40
Modulation OFDM
Effective transfer rate TCP/IP  500Mbps
Manageability 802.1D Ethernet Bridge
Quality of Service(QoS)
IGMO(IPv4)Snooping&MLD(IPv6)Snooping
Voltage range DC 10V-80V
Operating temperature -40℃-85℃
Size 123*97*47(mm)(L×W×H)
Weight 0.25kg
Operating environment Operating humidity:10%-85% (no condense)

1.2 FEATURES

(1) Packet loss:≤0.1%(100M,load 70%).
(2) Support 7*24 hours all weather operation.
(3) Hardware watch dog function.
(4) PING≤20MS.

1.3 IMMUNITY OF ESD

The testing voltage which the device should be beared: ±6kV direct Discharge, ±8kV air discharge. Discharge number in Each sensitive testing point: Plus-n-Minus 10 times each, Every time the discharge interval is 1 s, according to B/T 17626.2-2006.

1.4 IMMUNITY OF ELECTRICAL FAST TRANSIENT IMPULSE GROUP(COMMON MODE)
The testing voltage which the device should be beared:
between the power supply voltage port and ground: ±2.0kV;
between signal circuit and ground: ±1.0kV;
repetition frequency: 5KHz, test duration: 1 min/ time;
testing times: Plus-n-Minus 5 times each. According to GB/T 17626.4-2008.
1.5 ANTI INTERFERENCE OF SURGE IMPACT
The testing voltage which the device should be beared: ±2kV;
The interval of continuous impulses: 1min/time;
Test number: Plus-n-Minus 5 times each. According to GB/T 17626.5-2008.(protection: all models protection and varistor series of
discharge tube type)
1.6 ANTI- VIBRATION

Meet the demand of MX3 in TB1433(0-200Hz,2g acceleration, maximum amplitude 7mm), interface with no loose, device with no Sealing off and drop in the test